Improvement of the Russian National Secondary Standard of the Unit of Length Using Latest Ultra-Stable Laser Equipment
https://doi.org/10.32603/1993-8985-2019-22-4-109-114
Аннотация
Introduction. Increasing demands of precise geometry measurements by science and industry cause the necessity of improvement in an associated branch of legal and practical metrology. One of the most significant fields is the measurement of internal dimensions and so the issues with the unit of meter transfer. Now we face the situation when the current accuracies of National standards of different levels in corresponding traceability chain (reference rings measurements) get close to each other. This means that we have to make the standard of upper level more precise. One of the obvious ways is to apply the latest ultra-stable laser locked to a frequency comb.
Objective. The objective is to propose possibilities for improvement of the National secondary standard of the unit of length by researching its measuring capabilities to minimize measurement uncertainty.
Materials and methods. The calculation of expanded uncertainty of internal diameter measurements by the National secondary standard of the unit of length is performed according to the international document «Guide to the Expression of Uncertainty in Measurement» JCGM 100:2008 approved by BIPM. The secondary standard research results represented in previous reports and publications are also taken into consideration.
Results. Detailed uncertainty budget for the proposed measuring system is given as well as graphical data representing the accuracy improvement.
Conclusion. Actions for minimization of measurement uncertainty components of the National secondary standard of the unit of length in the field of reference ring internal diameter measurements in combination with state-of-the-art laser interferometer system improve it to the next frontiers of accuracy and precision.
Ключевые слова
Об авторах
Andrew A. MosckalevРоссия
Cand. Sci. (Engineering) (2018), Senior Researcher of the Department of Geometric Measurements
Ardi Rahman
Россия
Master of Engineering (M.Eng.), (2019) Saint Petersburg Electrotechnical university (LETI). Researcher at the national metrology institute of Indonesia called BSN
Список литературы
1. Rosstandart order № 2840 dated 29.12.2018. Submission of the State Verification Schedule for Measuring Instruments in the Range of Length from 1•10-9 to 100 m and Wavelength in the Range of 0.2 to 50 μm. Available at: https://www.gost.ru/portal/gost/home/activity/documents/ orders#/order/75693 (accessed 17.08.2019). (In Russ.)
2. GOST R 8.763-2011. State System for Ensuring Uniform Measurement. State Verification Schedule for Measuring Instruments in the Range of Length from 1•10-9 to 50 m and Wavelength in the Range of 0.2 to 50 μm. Moscow, Standardinform, 2013, 8 p. (In Russ.)
3. Bourdun G. D., Markov B. N. Metrology Basics. Moscow, Standards Publishing, 1985, 256 p. (In Russ.)
4. Farago F. T., Curtis M. A. Handbook of Dimensional Measurement. NY, Industrial Press Inc., 1994, 580 p.
5. Rahman A., Mosckalev A. Reducing Uncertainty of Standard Reference Ring Measurement Up to 50 nm by Means of Non-Contact Method. Proc. SPIE Optics + Optoelectronics. Prague, Czech Republic, 2019. doi: 10.1117/12.2520381
6. Mosckalev A., Rahman A. Research and Improvement of Laser Interferometric System in the Field of Non-Contact Measurements of Reference Rings. Techniques, technologies, engineering. 2018, no 3, pp. 18–22.
7. Abramova L. Yu., Brzhezinskii V. M., Bryukhovetskaya E. B., Solov’ev V. S., Khavinson L. F. The COOMET Comparisons of the Standard Measures of Internal Diameters. Measurement Techniques. 2006, vol. 49, no. 1, pp. 87–92. doi: 10.1007/s11018-006-0068-x
8. Batarchoukova N. R., Earickova L. A. Wavelengths of Monochromatic Light Sources and Refraction Coefficients in Standard Air. Moscow, Standards committee publishing, 1968 19 p. (In Russ.)
9. Logvinyuk E. Current Status of VNIIM Standard of Unit in the Field of Geometric Measurements. Proc. 28th Intern. scientific symp. "Metrology and metrology assurance 2018". Sozopol, 2018, pp. 53–56.
10. Chekirda K. V., Zakharenko Y. G., Kononova N. A., Phomkina Z. V. Current Status and Development Prospective of the Reference Base in the Length Measurements Field. Proc. IX Intern. Symp. "Metrology of Time and Space". Mendeleyevo, 2018, pp. 190–194.
11. Mosckalev A. A. Development and Research of High-Accurate Measuring Set for Thread Joints Metrology Assurance. Ph. D. degree author’s abstract, 2017.
12. Novikova S. I. Thermal Expansion of Solid Bodies. Мoscow, Science, 1974, 294 p. (In Russ.)
13. Zakharenko Y. G., Kononova N. A., Leibengardt G. I., Chekirda K. V. The Thirty-Meter Laser Interference Comparator Which Forms Part of the State Primary Standard of the Unit of Length – the Meter. Measurement Techniques. 2012, vol. 55, no. 5, pp. 519–525. doi: 10.1007/s11018-012-9992-0
14. Bartl J., Sevcik R., Fira R. Device for Ring Gauges Calibration. Proc. 7th International conference MEASUREMENT 2009. Slovakia, 2009, pp. 290–293.
15. JCGM 100:2008. Evaluation of measurement data – Guide to the expression of uncertainty in measurement. 2008б 134 p. Available at: https://www.bipm.org/ en/publications/guides/gum.html (accessed 17.08.2019).
16. Mosckalev A. High-accurate measurements of thread gages using the Labconcept NANO horizontal instrument. Proc. 24th National scientific symp. with intern. participation "Metrology and metrology assurance 2014". Sozopol, 2014, pp. 480–485.
Рецензия
Для цитирования:
Mosckalev A.A., Rahman A. Improvement of the Russian National Secondary Standard of the Unit of Length Using Latest Ultra-Stable Laser Equipment. Известия высших учебных заведений России. Радиоэлектроника. 2019;22(4):109-114. https://doi.org/10.32603/1993-8985-2019-22-4-109-114
For citation:
Mosckalev A.A., Rahman A. Improvement of the Russian National Secondary Standard of the Unit of Length Using Latest Ultra-Stable Laser Equipment. Journal of the Russian Universities. Radioelectronics. 2019;22(4):109-114. https://doi.org/10.32603/1993-8985-2019-22-4-109-114