<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">radioelectronics</journal-id><journal-title-group><journal-title xml:lang="ru">Известия высших учебных заведений России. Радиоэлектроника</journal-title><trans-title-group xml:lang="en"><trans-title>Journal of the Russian Universities. Radioelectronics</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">1993-8985</issn><issn pub-type="epub">2658-4794</issn><publisher><publisher-name>Saint Petersburg Electrotechnical University</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.32603/1993-8985-2018-21-6-111-117</article-id><article-id custom-type="elpub" pub-id-type="custom">radioelectronics-281</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>ПРИБОРЫ МЕДИЦИНСКОГО НАЗНАЧЕНИЯ, КОНТРОЛЯ СРЕДЫ, ВЕЩЕСТВ, МАТЕРИАЛОВ И ИЗДЕЛИЙ</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>MEDICAL DEVICES, ENVIRONMENT, SUBSTANCES, MATERIAL AND PRODUCT</subject></subj-group></article-categories><title-group><article-title>ИССЛЕДОВАНИЕ ВЛИЯНИЯ ДЛИНЫ СИГНАЛА ЭЭГ НА ТОЧНОСТЬ КЛАССИФИКАЦИИ УРОВНЕЙ АНЕСТЕЗИИ</article-title><trans-title-group xml:lang="en"><trans-title>INVESTIGATION OF EEG SIGNAL LENGTH INFLUENCE ON ACCURACY OF ANESTHESIA LEVELS CLASSIFICATION</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Аль-Гаили</surname><given-names>М. А.</given-names></name><name name-style="western" xml:lang="en"><surname>Al-Ghaili</surname><given-names>Mokhammed A.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Аль-Гаили Мохаммед Ахмед Хамуд – аспирант кафедры биотехнических систем Санкт-Петербургского государственного электротехнического университета "ЛЭТИ" им. В. И. Ульянова (Ленина). Автор пяти научных публикаций. Сфера научных интересов – цифровая обработка биомедицинских сигналов, машинное обучение, распознавание образов.</p><p>ул. Профессора Попова, д. 5, Санкт-Петербург, 197376</p></bio><bio xml:lang="en"/><email xlink:type="simple">alghily@mail.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Калиниченко</surname><given-names>А. Н.</given-names></name><name name-style="western" xml:lang="en"><surname>Kalinichenko</surname><given-names>Alexander N.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Калиниченко Александр Николаевич – доктор технических наук (2009), старший научный сотрудник (1998), профессор кафедры биотехнических систем Санкт-Петербургского государственного электротехнического университета "ЛЭТИ" им. В. И. Ульянова (Ленина). Автор более 160 научных работ. Сфера научных интересов – компьютерный анализ биомедицинских сигналов, машинное обучение, распознавание образов.</p><p>ул. Профессора Попова, д. 5, Санкт-Петербург, 197376</p></bio><bio xml:lang="en"/><email xlink:type="simple">ank-bs@yandex.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Каид</surname><given-names>М. Р.</given-names></name><name name-style="western" xml:lang="en"><surname>Qaid</surname><given-names>Mokhammed R.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Мохаммед Ракиб Табит Каид – магистр по направлению Биотехнические системы и технологии (2018, Санкт-Петербургский государственный электротехнический университет "ЛЭТИ" им. В. И. Ульянова (Ленина)). Сфера научных интересов – цифровая обработка биомедицинских сигналов.</p><p>ул. Профессора Попова, д. 5, Санкт-Петербург, 197376</p></bio><bio xml:lang="en"/><email xlink:type="simple">mkaid@gmail.com</email><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru">Санкт-Петербургский государственный электротехнический университет "ЛЭТИ" им. В. И. Ульянова (Ленина)<country>Россия</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2018</year></pub-date><pub-date pub-type="epub"><day>28</day><month>12</month><year>2018</year></pub-date><volume>0</volume><issue>6</issue><fpage>111</fpage><lpage>117</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Аль-Гаили М.А., Калиниченко А.Н., Каид М.Р., 2018</copyright-statement><copyright-year>2018</copyright-year><copyright-holder xml:lang="ru">Аль-Гаили М.А., Калиниченко А.Н., Каид М.Р.</copyright-holder><copyright-holder xml:lang="en">Al-Ghaili M.A., Kalinichenko A.N., Qaid M.R.</copyright-holder><license license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://re.eltech.ru/jour/article/view/281">https://re.eltech.ru/jour/article/view/281</self-uri><abstract><p>Одной из важнейших задач при проведении хирургических операций является оценка глубины анестезии пациента. Глубина общей анестезии традиционно оценивалась с помощью гемодинамических признаков, которые плохо коррелируют с уровнем сознания пациента. Сигналы электроэнцефалограммы (ЭЭГ) содержат ценную информацию о процессах в мозге пациента, поэтому анализ ЭЭГ рассматривается как один из наиболее полезных методов в исследовании и оценке глубины анестезии в клинических применениях. Нелинейный анализ для оценки глубины анестезии позволяет получить информацию, которая не может быть получена с использованием методов спектрального анализа ЭЭГ. Формирование комплекса диагностически значимых показателей ЭЭГ во время анестезии дает возможность адекватно описать эти сложные процессы и изменения с помощью совместного использования четырех параметров ЭЭГ: SE, BSR, SEF95, RBR. Целью работы является исследование влияния длительности анализируемого фрагмента сигнала ЭЭГ на точность оценки уровней анестезии с помощью алгоритма линейного дискриминантного анализа и определение длины сигнала ЭЭГ, при которой получается приемлемая точность разделения уровней наркоза с помощью этих параметров. Предложен новый метод классификации уровней анестезии по ЭЭГ. Показана возможность классификации уровней анестезии с помощью совместного использования рассматриваемых параметров ЭЭГ (SE, BSR, SEF95, RBR). Метод может быть использован в мониторах анестезии, служащих для контроля глубины наркоза в целях выбора подходящей дозы анестезирующих препаратов во время операций, что позволит избежать как случаев интраоперационного пробуждения, так и излишне глубокого наркоза.</p></abstract><trans-abstract xml:lang="en"><p>This paper considers one of the challenging tasks during surgical procedure, i.e. depth of anasthesia estimate. The purpose of this paper is to investigate the effect of the analyzed EEG signal fragment duration on the accuracy of anesthesia level estimate using the linear discriminant analysis algorithm and determining the EEG signal length, which yields acceptable accuracy of anesthesia level separation using these parameters.</p><p>A new method for classifying EEG anesthesia levels is proposed. The possibility of classifying levels of anesthesia is demonstrated by means of sharing the EEG parameters under consideration (SE, BSR, SEF95, RBR). The method can be used in anesthesia monitors that are used to monitor the depth of anesthesia in order to select the appropriate dose of anesthetic drugs during operations, thus avoiding both cases of intraoperative arousal and excessively deep anesthesia.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>ЭЭГ</kwd><kwd>оценка глубины анестезии</kwd><kwd>дискриминантный анализ</kwd><kwd>спектральная энтропия</kwd><kwd>BIS-индекс</kwd></kwd-group><kwd-group xml:lang="en"><kwd>EEG</kwd><kwd>anesthesia depth estimation</kwd><kwd>linear discriminant analysis</kwd><kwd>spectral entropy</kwd><kwd>BIS-index</kwd></kwd-group><funding-group xml:lang="ru"><funding-statement>Работа выполнена при финансовой поддержке РФФИ, проект №16-07-00722 "Алгоритмы распознавания и анализа нарушений сердечного ритма, имеющих хаотическую природу, для систем непрерывного кардиологического наблюдения"</funding-statement></funding-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Classification of EEG Signals Based on Pattern Recognition Approach / H. U. Amin, W. Mumtaz, A. R. Subhani, M. N. M. Saad, A. S. Malik // Frontiers in Computational Neuroscience. 2017. Vol. 11, art.103. P. 1–12.</mixed-citation><mixed-citation xml:lang="en">Amin H. U. , Mumtaz W., Subhani A. R., Saad M. N. M., Malik A. S. Classification of EEG Signals Based on Pattern Recognition Approach. Frontiers in Computational Neuroscience. 2017, vol. 11, art.103, pp. 1–12.</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Thornton C., Jones J. G. Evaluating Depth of Anesthesia: Review of Methods // International Anesthesiology Clinics. 1993. Vol. 31, iss.4. P. 67–88.</mixed-citation><mixed-citation xml:lang="en">Thornton C., Jones J. G. Evaluating Depth of Anesthesia: Review of Methods. International Anesthesiology Clinics. 1993, vol. 31, iss.4, pp. 67–88.</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Awareness During Anesthesia: a Closed Claims Analysis / K. B. Domino, K. L. Posner, R. A. Caplan, F. W. Cheney // Anesthesiology. 1999. Vol. 90. P. 1053–1061.</mixed-citation><mixed-citation xml:lang="en">Domino K. B., Posner K. L., Caplan R. A., Cheney F. W. Awareness During Anesthesia: a Closed Claims Analysis. Anesthesiology. 1999, vol. 90, pp. 1053–1061.</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Monitoring the Depth of Anesthesia Using Entropy Features and an Artificial Neural Network / R. Shalbaf, H. Behnam, J. W. Sleigh, A. Steyn-Ross, L. J. Voss // J. of Neuroscience Methods. 2013. Vol. 218, iss. 1. P. 17–24.</mixed-citation><mixed-citation xml:lang="en">Shalbaf R., Behnam H., Sleigh J. W., Steyn-Ross A., Voss L. J. Monitoring the Depth of Anesthesia Using Entropy Features and an Artificial Neural Network. Journal of Neuroscience Methods. 2013, vol. 218, iss. 1, pp. 17–24.</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Classification of Wakefulness and Anesthetic Sedation Using Combination Feature of EEG and ECG / B. Lee, D. Won, K. Seo, H. J. Kim, S. Lee // Proc. of 2017 5th Intern. Winter Conf. on Brain-Computer Interface (BCI). Sabuk, South Korea, 9–11 Jan. 2017. Piscataway: IEEE, 2017. P. 88–90. doi: 10.1109/IWW-BCI.2017.7858168</mixed-citation><mixed-citation xml:lang="en">Lee B., Won D., Seo K., Kim H. J., Lee S. Classification of Wakefulness and Anesthetic Sedation Using Combination Feature of EEG and ECG. Proc. of 2017 5th International Winter Conference on Brain-Computer Interface (BCI). Sabuk, South Korea, 9–11 Jan. 2017. Piscataway: IEEE, 2017, pp. 88–90. doi: 10.1109/IWWBCI.2017.7858168</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Tong S., Thakor N. V. Quantitative EEG Analysis Methods and Clinical Applications. Norwood: Artech House, 2009. 421 p.</mixed-citation><mixed-citation xml:lang="en">Tong S., Thakor N. V. Quantitative EEG Analysis Methods and Clinical Applications. Norwood: Artech House, 2009, 421 p.</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Wavelet Entropy Based Classification of Depth of Anesthesia / V. K. Benzy, E. A. Jasmin, R. C. Koshy, F. Amal // 2016 Intern. Conf. on Computational Techniques in Information and Communication Technologies (ICCTICT), New Delhi, India, 11–13 March 2016. Piscataway: IEEE, 2016. P. 521–524. doi: 10.1109/ICCTICT.2016.7514635</mixed-citation><mixed-citation xml:lang="en">Benzy V. K., Jasmin E. A., Koshy R. C., Amal F. Wavelet Entropy Based Classification of Depth of Anesthesia. 2016 International Conference on Computational Techniques in Information and Communication Technologies (ICCTICT), New Delhi, India, 11–13 March 2016. Piscataway: IEEE, 2016, pp. 521–524. doi: 10.1109/ICCTICT.2016.7514635</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Description of the Entropy Algorithm as Applied in the Datex-Ohmeda S/5 Entropy Module / H. Viertiö-Oja, V. Maja, M. Särkelä, P. Talja, N. Tenkanen, H. TolvanenLaakso, M. Paloheimo, A. Vakkuri, A. Yli-Hankala, P. Meriläinen // Acta Anaesthesiologica Scandinavica. 2004. Vol 48, iss. 2. P. 154–161.</mixed-citation><mixed-citation xml:lang="en">Viertiö-Oja H., Maja V., Särkelä M., Talja P., Tenkanen N., Tolvanen-Laakso H., Paloheimo M., Vakkuri A., Yli-Hankala A., Meriläinen P. Description of the Entropy Algorithm as Applied in the Datex-Ohmeda S/5 Entropy Module. Acta Anaesthesiologica Scandinavica. 2004, vol 48, iss. 2, pp. 154–161.</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Monitoring the Depth of Anesthesia from Rat EEG Using Modified Shannon Entropy Analysis / Y. Yoon, T. Kim, D. Jeong, S. Park // 2011 Annual Intern. Conf. of the IEEE Engineering in Medicine and Biology Society. Boston, MA, USA, 30 Aug.–3 Sept. 2011, Piscataway: IEEE, 2011. P. 4386–4389. doi: 10.1109/IEMBS.2011.6091088.</mixed-citation><mixed-citation xml:lang="en">Yoon Y., Kim T., Jeong D., Park S. Monitoring the Depth of Anesthesia from Rat EEG Using Modified Shannon Entropy Analysis. 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society. Boston, MA, USA, 30 Aug.–3 Sept. 2011, Piscataway: IEEE, 2011, pp. 4386–4389. doi: 10.1109/IEMBS.2011.6091088.</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">A Comparison of Different Classification Algorithms for Determining the Depth of Anesthesia Level on a New Set of Attributes / A. Arslan, B. Şen, F. V. Çelebi, M. Peker, A. But // 2015 Intern. Symp. on Innovations in Intelligent Systems and Applications (INISTA), Madrid, Spain, 2–4 Sept. 2015. Piscataway: IEEE, 2015. P. 1–7. doi: 10.1109/INISTA.2015.7276738</mixed-citation><mixed-citation xml:lang="en">Arslan A., Şen B., Çelebi F. V., Peker M., But A. A Comparison of Different Classification Algorithms for Determining the Depth of Anesthesia Level on a New Set of Attributes. 2015 International Symposium on Innovations in Intelligent Systems and Applications (INISTA), Madrid, Spain, 2–4 Sept. 2015. Piscataway: IEEE, 2015, pp. 1–7. doi: 10.1109/INISTA.2015.7276738</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">Аль-Гаили М. А., Калиниченко А. Н. Оценка глубины анестезии на основе совместного анализа частотных и временных параметров ЭЭГ // Изв. СПбГЭТУ “ЛЭТИ”. 2018. № 3. С 80–85.</mixed-citation><mixed-citation xml:lang="en">Al-Ghaili M. A., Kalinichenko A. N. Evaluation of Depth of Anesthesia Based on Joint Analysis of EEG Frequency and Time Parameters. Izvestiya SPBGETU “LETI” [Proceedings of Saint Petersburg Electrotechnical University], 2018, no. 3, pp. 80–85. (In Russian)</mixed-citation></citation-alternatives></ref><ref id="cit12"><label>12</label><citation-alternatives><mixed-citation xml:lang="ru">Аль-Гаили М. А. Оценка стадий глубокой анестезии по электроэнцефалограмме на основе спектрального анализа // Изв. СПбГЭТУ “ЛЭТИ”. 2017. № 2. С 75–79.</mixed-citation><mixed-citation xml:lang="en">Al-Ghaili M. A. Evaluation of Deep Anesthesia Stages by Electroencephlogram Based on Spectral Analysis. Izvestiya SPBGETU “LETI” [Proceedings of Saint Petersburg Electrotechnical University]. 2017. № 2. С 75–79. (In Russian)</mixed-citation></citation-alternatives></ref><ref id="cit13"><label>13</label><citation-alternatives><mixed-citation xml:lang="ru">Kalinichenko A. N., Manilo L. A., Nemirko A. P. Analysis of Anesthesia Stages Based on the EEG Entropy Estimation // Pattern Recognition and Image Analysis. Advances in Mathematical Theory and Applications. 2015. Vol. 25, № 4. P. 632–641.</mixed-citation><mixed-citation xml:lang="en">Kalinichenko A. N., Manilo L. A., Nemirko A. P. Analysis of Anesthesia Stages Based on the EEG Entropy Estimation. Pattern Recognition and Image Analysis. Advances in Mathematical Theory and Applications. 2015, vol. 25, № 4, pp. 632–641.</mixed-citation></citation-alternatives></ref><ref id="cit14"><label>14</label><citation-alternatives><mixed-citation xml:lang="ru">Duda R. O., Hart P. E., Stork D. H. Pattern Classification: 2nd ed. NY: Wiley Interscience, 2001. 654 p.</mixed-citation><mixed-citation xml:lang="en">Duda R. O., Hart P. E., Stork D. H. Pattern Classification: 2nd ed. NY: Wiley Interscience, 2001, 654 p.</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
